Samrt Contactless IC Card Digital Heat Meter DN25
General Introduction
Samrt Contactless IC Card Digital Heat Meter can measure heat power passed through pipes. It is more advanced than RLB since it is prepaid and use RF card to activate meter. It consists of flow sensor, microprocessor, temperature sensor and prepaid module. It also can be used to measure cold power if connect temperature sensors reversely.
Characteristics
1. Prepaid, RF card, waterproof and reliable performance.
2. Latest patent technique of wireless digital monitoring to supervise and calculate heat power.
3. No mechanic gears, no magnetism sensor, wear resistance, anti-corrosive and anti-attack.
4. Alarming when low voltage.
5. Alarming when temperature sensor is disconnected or in case of short circuit.
6. Flow rate has 8 levels and can be separately adjusted automatically, high accuracy.
7. Smart lower power consumption according to flow speed.
8. Update online.
9. Data backup and automatic correction.
10. Ultra-low energy consumption.
11. Electric floating ball valve patent technique
Technique Specifications
Flow Sensor | Caliber | Common Flow Rate | Min Flow Rate | Max Flow Rate | |||
15mm | 1500L/h | 30L/h | 3000L/h | ||||
20mm | 2500L/h | 50L/h | 5000L/h | ||||
25mm | 3500L/h | 70L/h | 7000L/h | ||||
Min Flow Rate for Display: | 0.01m3 (working state) | 0.00001m3(testing state) | |||||
Min Heat Power for Display: | 1kWh (working state) | 0.001kWh (testing state) | |||||
Working Condition of Temperature Sensor | Min Temperature Difference | 1 or 3 Celsius | |||||
Max Temperature Difference | 90 Celsius | ||||||
Min Display Temperature | 0.1 Celsius | ||||||
Static Working Current | < 7μA | ||||||
Battery Service Life | > 5 years | ||||||
Digit Number of LCD | 8 numbers | ||||||
Max Accumulated Working Time | 4.2x109 hours (Meter only displays final 8 numbers when accumulated working time is more than 99999999 hours) | ||||||
Max Accumulated Flow Rate | 4.2x109 m3(Meter only displays final 8 numbers when accumulated flow rate is more than 999999.99m3) | ||||||
Accuracy | Grade B | ||||||
Alarm kWh | 1000kWh | ||||||
Pressure Resistance | 1.6MPa |