Ultrasonic Contactless IC Card Heat Flow Meter

Ultrasonic Contactless IC Card Heat Flow Meter
Product Detailed
Related Categories:Flow Meters
1.IC card heat flow meter 2.LCD display 3.High sensitivity and accuracy 4.Meets special customization 5.ISO9001,CE,OEM

General introduction

RLBF-C series heat flow meter is consisted of flow sensor, microprocessor and matched pair temperature sensor.

Characteristics

1. Alarms when voltage is low.

2. Automatic data correction technology.

3. Alarms when the temperature sensor is disconnected or has a short cut.

4. High definition and wide temperature LCD display.

5. Flow rate has 8 levels and are separately adjusted, with high precision.

6. Motor-driven float ball valve patent technology

7. Intelligent blockage resistant and valve rust remove technology

8. Alarms by closing the valve when remaining heat power is on limiting level

9. Automatically valve testing technology

10. Ultra-low energy consumption (static power consumption is less than 7uA ).

11. The tube adopts forging technology.

  

Technique Specifications

Flow sensor

Caliber(mm)

Common flow rate

Mini flow rate

 

Max flow rate

 

DN15

1.5 m3/h

0.03 m3/h

3.0 m3/h

DN20

2.5 m3/h

0.05 m3/h

5.0 m3/h

DN25

3.5 m3/h

0.07 m3/h

7.0 m3/h

Minimum display of flow rate:   0.01 m3 (working status)    0.00001 m3 (testing status) 

Minimum display of heat power: 1kWh(working status)     0.001kWh(testing status)

Temperature sensor

Min temperature difference

1°C or 3°C

Max temperature difference

90°C

Min display temperature

0.1°C

Static working current

< 7μA

Power supply

3.6V, by battery

Battery service life

> 6 years

Digit number of LCD screen

8 number

Max accumulated working time

4.2x109 hours(Only final 8 number can be displayed when accumulated working time is more than 99999999 hours)

Max accumulated flow rate

4.2x109 m3 (Only final 8 number can be displayed when accumulated flow rate is more than 999999.99 m3)

Accuracy

Grade 2 or Grade 3

Pressure resisting

1.6Mpa

Loss of pressure

≤0.025Mpa

Limiting Level for alarm

1000kWh

The Minimum unit for purchasing heat power

1kWh

Working status indicator

Twinkling of our company’s logo on the top left corner of the LCD

RLBF-C---measure by heat power unit, DN15/20/25

Ultrasonic Contactless IC Card Heat Flow Meter